Compound/IV Print Options

Compound/IV Print Options are used to set up the information to print on the label. These label options serve as the defaults for the Label Options on the Compound/IV Template screen depending on the compound type (Compound, Large Volume IV or Piggyback) set on the template. These options are blank by default and must be configured for use.

To set up Compound/IV label print options:

1. Access PrimeCare.

2. Click Store Control. Select Label Options and click Compound/IV Printing Options. The Compound/IV Label Options window displays:

3. Use the definitions below to set up the options for Compound, Large Volume IV and Piggyback labels:

Code Length Field Definition
Blank   Last Line is Blank
A 8 System Generated Expiration Date of the prescription.
B 8 Original Rx Date
C 10 Remaining Refills
  
NOTE: Type the last line option selected here in the Last Line Option field on the Prescription Record/Additional Information screen. Options include: type P00 to print May Refill, 000 to print No Refill, or type C in the 1st position to omit printing any refill information.

D

12 Prints the Pharmacist's Name signed onto the system at the time of filling.
E 2 Prints the Patient Group Code from the Patient Record/Additional Information screen.
F 5 Prints the Room Number from the Patient Record/General Information screen
G 10 Prints the Lot Number from the Drug Record/General Information screen.
H 5 Prints the Manufacturer from the Drug Record/Clinical screen.
I 8 Prints the Stop Date from Store Control/Store Level Options/Rx Filling Options and Defaults.
J 9 Prints the DEA Number from the Prescriber Record.
K 6 Prints the price of the prescription, excluding sales tax.
L 8 Prints the Exp Date from Store Control/Store Level Options/Rx Filling Options and Defaults.
M 7  
N 13 Prints the Drug NDC Number.

4. When print options are complete, click .

 

Return to Label Options